Suppliers
Contact Us
![]() Voortstraat 49, 1910 Kampenhout BELGIUM Tel 0032 16 58 90 45 Fax 0032 16 50 90 45 This email address is being protected from spambots. You need JavaScript enabled to view it.">This email address is being protected from spambots. You need JavaScript enabled to view it. |
GENTAUR BULGARIA
53 Iskar Str. 1191 Kokalyane, Sofia
Tel 0035924682280
Fax 0035929830072
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR France SARL
9, rue Lagrange, 75005 Paris
Tel 01 43 25 01 50
Fax 01 43 25 01 60
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
GmbH Marienbongard 20
52062 Aachen Deutschland
Tel (+49) 0241 56 00 99 68
Fax (+49) 0241 56 00 47 88 This email address is being protected from spambots. You need JavaScript enabled to view it." style="font-family: Arial, Tahoma, Verdana, Helvetica; line-height: 15.59375px; ">
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
This email address is being protected from spambots. You need JavaScript enabled to view it." style="font-size: 12px; line-height: 1.3em;">
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR Ltd.
Howard Frank Turnberry House
1404-1410 High Road
Whetstone London N20 9BH
Tel 020 3393 8531
Fax 020 8445 9411
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR Poland Sp. z o.o.
ul. Grunwaldzka 88/A m.2
81-771 Sopot, Poland
Tel 058 710 33 44
Fax 058 710 33 48
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR Nederland BV
Kuiper 1
5521 DG Eersel Nederland
Tel 0208-080893
Fax 0497-517897
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR SRL IVA IT03841300167
Piazza Giacomo Matteotti, 6, 24122 Bergamo
Tel 02 36 00 65 93
Fax 02 36 00 65 94
This email address is being protected from spambots. You need JavaScript enabled to view it.">This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR Spain
Tel 0911876558
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
Genprice Inc, Logistics
547, Yurok Circle
San Jose, CA 95123
Phone/Fax:
(408) 780-0908
This email address is being protected from spambots. You need JavaScript enabled to view it.
GENPRICE Inc. invoicing/ accounting:
6017 Snell Ave, Suite 357
San Jose, CA. 96123
Serbia,
Macedonia,
Montenegro,
Croatia:
Tel 0035929830070
Fax 0035929830072
This email address is being protected from spambots. You need JavaScript enabled to view it.">This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR Romania
Tel 0035929830070
Fax 0035929830072
This email address is being protected from spambots. You need JavaScript enabled to view it.">This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR Greece
Tel 00302111768494
Fax 0032 16 50 90 45
This email address is being protected from spambots. You need JavaScript enabled to view it.">This email address is being protected from spambots. You need JavaScript enabled to view it.
Other countries
Luxembourg +35220880274
Schweiz Züri +41435006251
Danmark +4569918806
Österreich +43720880899
Ceská republika Praha +420246019719
Ireland Dublin +35316526556
Norge Oslo +4721031366
Finland Helsset +358942419041
Sverige Stockholm +46852503438
Magyarország Budapest +3619980547
Flame Photometer (AE-SFP100)
Key Features:
* Duel channel, LCD display.
* Pre-selection of flame sizes;
* A flameout protection device;
* K and Na testing at the same time.
Applications:
Flame Photometer is used for analyzing & measuring the content & concentration of K, Na elements.
* Testing cement, glass, ceramics, refractory materials and other construction materials;
* Testing fertilizers and soil;
* Testing products of mining, petroleum, metallurgy, and chemical products;
* Testing pharmaceutical, beverages and other food;
* MSW testing;
* Various laboratory tests for scientific research, health, education and other fields.
Ordering Information:
Order Code |
Description |
AE-SFP40 |
With air-compressor.Measurement Range: K: 0-15, 0-40ug/mL; Na: 0-40, 0-80ug/mL. |
AE-SFP60 |
With air-compressor. Measurement Range: K: 0-15, 0-40, 0-60ug/mL; Na: 0-40, 0-80, 0-120ug/mL. |
AE-SFP100 |
With air-compressor, micro-printer or PC software. Measurement Range: K: 0-15, 0-40, 0-60, 0-100ug/mL; Na: 0-40, 0-80, 0-120, 0-160ug/mL. |
Technical Specifications:
Linearity Range |
K: detection limit ≤ 0.004mmol/L; Na: detection limit ≤ 0.008mmol/L |
Linearity Error |
K: ≤ 0.005mmol/L(0.0100~0.0800)mmol/L; Na: ≤ 0.03mmol/L(0.0500~0.400)mmol/L. |
Repeatability |
Conduct 7 consecutive independent tests for one standard solution, the relative standard deviation: ≤ 3%. |
Stability |
Continuous sampling of standard solution, the biggest change in the relative volume in 15s: ≤ 3%; Test once every minute, and test 6 times in total, the biggest change in the relative volume: ≤ 15%. |
Response Time |
Response time <8s |
Suction Jet of Samples |
Suction jet of samples <6mL/min |
Dimension |
380x770x570mm |
Weight |
18kg |
Flame Photometer (AE-SFP500)
Application:
This instrument is used for analyzing & measuring the content & concentration of elements (K, Na, Li, Ca, Ba).
It can be widely applied to agriculture (soil, fertilizer, tobacoo), industry (cement, glass, ceramics, mineral
or ore powder, fireproof material), food (wine, water), laboratory, clinical experiments and pathology research
(serum, urine, plasma), etc.
Characteristics:
* With 5 channels and be able to detect K, Na, Li, Ca, Ba 5 elements. With K, Na, Li, Ca, Ba five filters, which can
detect three kinds of elements, show three kinds of element content simultaneous.
* Operates on propane, butane or liquefied petroleum gas.
* Standard accessories: air-compressor, PC software or micro-printer.
* LCD Display, touch panel with numeric keypad.
* Single point calibration & calibration curve can be saved.
* RS232 interface, external computer or printer. With a mist separator.
Ordering Information:
Order Code |
Description |
AE-SFP500 |
Measurement Range: K: 0-100ppm; Na: 0-100ppm; Li: 0-100ppm; Ca: 0-1000ppm; Ba: 0-3000ppm; Measurement Limit: K: 0.01ppm; Na: 0.01ppm; Li: 0.025ppm; Ca: 0.1ppm; Ba: 10ppm; |
AE-SFP401 |
Measurement Range: K: 0-100ppm; Na: 0-100ppm; Li: 0-100ppm; Ca: 0-1000ppm; Measurement Limit: K: 0.01ppm; Na: 0.01ppm; Li: 0.025ppm; Ca: 0.1ppm; |
AE-SFP402 |
Measurement Range: K: 0-100ppm; Na: 0-100ppm; Li: 0-100ppm; Ba: 0-3000ppm; Measurement Limit: K: 0.01ppm; Na: 0.01ppm; Li: 0.025ppm; Ba: 10ppm; |
AE-SFP301 |
Measurement Range: K: 0-100ppm; Na: 0-100ppm; Li: 0-100ppm; Measurement Limit: K: 0.01ppm; Na: 0.01ppm; Li: 0.025ppm; |
AE-SFP302 |
Measurement Range: K: 0-100ppm; Na: 0-100ppm; Ca: 0-1000ppm; Measurement Limit: K: 0.01ppm; Na: 0.01ppm; Ca: 0.1ppm; |
AE-SFP200 |
Measurement Range: K: 0-100ppm; Na: 0-100ppm; Measurement Limit: K: 0.01ppm; Na: 0.01ppm; |
Technical Specifications:
Drift |
≤ 3% (after 30 minutes when the instrument stability) |
Sample Rate |
4 ~ 6ml/min |
Linearity |
Better than the best results of the intermediate value of 2% (single-point CAL) |
Response Time |
<8s |
Time Stability |
Less than 15 seconds (when the sample was taken after the flame) |
Calibration Methods |
Straight line, broken line, secondary fitting |
Size & Weight |
530X510X580mm & 27kg |