Suppliers
Contact Us
![]() Voortstraat 49, 1910 Kampenhout BELGIUM Tel 0032 16 58 90 45 Fax 0032 16 50 90 45 This email address is being protected from spambots. You need JavaScript enabled to view it.">This email address is being protected from spambots. You need JavaScript enabled to view it. |
GENTAUR BULGARIA
53 Iskar Str. 1191 Kokalyane, Sofia
Tel 0035924682280
Fax 0035929830072
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR France SARL
9, rue Lagrange, 75005 Paris
Tel 01 43 25 01 50
Fax 01 43 25 01 60
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
GmbH Marienbongard 20
52062 Aachen Deutschland
Tel (+49) 0241 56 00 99 68
Fax (+49) 0241 56 00 47 88 This email address is being protected from spambots. You need JavaScript enabled to view it." style="font-family: Arial, Tahoma, Verdana, Helvetica; line-height: 15.59375px; ">
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
This email address is being protected from spambots. You need JavaScript enabled to view it." style="font-size: 12px; line-height: 1.3em;">
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR Ltd.
Howard Frank Turnberry House
1404-1410 High Road
Whetstone London N20 9BH
Tel 020 3393 8531
Fax 020 8445 9411
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR Poland Sp. z o.o.
ul. Grunwaldzka 88/A m.2
81-771 Sopot, Poland
Tel 058 710 33 44
Fax 058 710 33 48
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR Nederland BV
Kuiper 1
5521 DG Eersel Nederland
Tel 0208-080893
Fax 0497-517897
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR SRL IVA IT03841300167
Piazza Giacomo Matteotti, 6, 24122 Bergamo
Tel 02 36 00 65 93
Fax 02 36 00 65 94
This email address is being protected from spambots. You need JavaScript enabled to view it.">This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR Spain
Tel 0911876558
This email address is being protected from spambots. You need JavaScript enabled to view it." style="">This email address is being protected from spambots. You need JavaScript enabled to view it.
Genprice Inc, Logistics
547, Yurok Circle
San Jose, CA 95123
Phone/Fax:
(408) 780-0908
This email address is being protected from spambots. You need JavaScript enabled to view it.
GENPRICE Inc. invoicing/ accounting:
6017 Snell Ave, Suite 357
San Jose, CA. 96123
Serbia,
Macedonia,
Montenegro,
Croatia:
Tel 0035929830070
Fax 0035929830072
This email address is being protected from spambots. You need JavaScript enabled to view it.">This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR Romania
Tel 0035929830070
Fax 0035929830072
This email address is being protected from spambots. You need JavaScript enabled to view it.">This email address is being protected from spambots. You need JavaScript enabled to view it.
GENTAUR Greece
Tel 00302111768494
Fax 0032 16 50 90 45
This email address is being protected from spambots. You need JavaScript enabled to view it.">This email address is being protected from spambots. You need JavaScript enabled to view it.
Other countries
Luxembourg +35220880274
Schweiz Züri +41435006251
Danmark +4569918806
Österreich +43720880899
Ceská republika Praha +420246019719
Ireland Dublin +35316526556
Norge Oslo +4721031366
Finland Helsset +358942419041
Sverige Stockholm +46852503438
Magyarország Budapest +3619980547
Articles
NeuroPhore Drug Application System
- Up to 5 Channels of Iontophoretic or Pneumatic Drug Delivery
- Modular Design Allows Upgrades in the Future
- Low Noise & Automatic Current Compensation Circuitry
- Aids Troubleshooting with Unbalance & Out of Compliance Indicators
- External or Internal Control of Timing & Ejection Parameters
In the past few decades, the application of drugs and other dissolved agents from multibarrel electrodes/pipettes has evolved into a practical method of testing their effects on cells or cellular systems. The versatile NeuroPhore BH-2 System is designed to facilitate controlled ejection of fluids from multi-barrel micropipettes. Extracellular ejections of minute volumes can be delivered using up to fi ve pumps in serial or parallel. The ejection schedule for each pump can be independently programmed for sequential or simultaneous output. Ejection cycles can be internally timed, triggered manually, or synchronised to external events. This flexible system allows the use of Iontophoretic Pump Modules, Pneumatic Pump Modules or a combination of both. By interchanging the IP-2 Iontophoretic Pump Module with a PPM-2 Pneumatic Pump Module, the overall system capability can be expanded for simultaneous pressure and iontophoretic injection of drugs from a multibarrel pipette. The NeuroPhore BH-2 System was developed under the guidance of active researchers with extensive experience in iontophoretic techniques. These researchers needed a system to provide precise stimulation and quantitative control for ejection of drugs in their pharmacological studies of drug evoked responses. What emerged was the reliable, accurate, easy to use NeuroPhore BH-2 System that is capable of accommodating high impedance multi-barreled micro-electrode pipettes.
BH-2 Mainframe Chassis (includes BM-2 Balance Module & MS-2 Power Supply)
The BH-2 is prewired to accept one balance and control module and up to fi ve iontophoretic/pneumtic pump modules. The BM-2 Balance Module provides automatic current neutralisation as well as independent control of its current pump settings (from 0 - 500nA). The Balance Module includes digital system timing, clock, provisions for electrical and manual cycle start/stop, a single cycle/recycle switch and trigger/gate input terminals to initiate externally controlled eject pumping action of each module. Analogue input for balance or drive with override capability. Analogue output for monitoring of unbalance currents.
IP-2 Iontophoretic Module
Each IP-2 module includes controls for precise settings of current magnitude and polarity (retention 0 - 50 nA, ejection 0 - 500 nA. The actual current and polarity being delivered is continuously displayed digitally and can be externally monitored at the analog output terminal. Ejection Timing & Mode Switch